Search
Enter your search text here.
Results 15 - 21 of 132 for ac (0.0008 seconds)
SMS 2 [52.38% relevance]
-controlled motor control (wind/light), 230V AC (rail-mount variant) Awning control with … -controlled motor control (wind/light), 230V AC (rail-mount variant) SMS 2 The SMS 2 is used … SMS209 EAN: 4046929401173 Specifications: 230V AC, 2 NO contacts 10A potential-free Dimensions: 18 … high, the awning is extended automatically, and retracted again when the brightness decreases (this … ). If the wind speed is too high, the awning is retracted automatically. The SMS 2 also has an integrated … decreases (this automatic function can also be deactivated). If the wind speed is too high, the awning is … connected. The automatic shading system can be deactivated for a certain period of time by pressing an … variant SMS U2 (functionality differs). Suitable accessories SW 4 - Wind sensor with articular mount SL 2 - … SL 2 / SW 4 (EN) (1.3 MiB) Power rating of relay contacts (301.9 KiB) Technical data Type: SMS 2 Item no … EAN: 4046929401173 Specifications: 230V AC, 2 NO contacts 10A
https://www.schalk.de/motor-controllers/articles/sms-2.en.html - 76.59 KiB
RSW 1 [52.38% relevance]
relay, 1 CO 16A, versions: 12V UC, 24V UC, 230V AC RSW 1 Switching and control relay RSW 1 … contacts (301.9 KiB) Technical data RSW 1 (230V AC) Type: RSW 1 (230V AC) Item no.: RSW109 EAN: … 4046929601146 Specifications: 230V AC, 1 CO 16A Dimensions: 18 x 55 mm Technical data … mm RSW 1 (12V UC), , RSW 1 (24V UC), RSW 1 (230V AC), Download db_rsw1_rssu1_en.pdf, Download … and power dissipation. High continuous load capacity due to 16A changeover contact. Also available as … continuous load capacity due to 16A changeover contact. Also available as compact flush-mounted version … RSW U1 with 13A NO contact. Additional information Datasheet RSW 1 / RSS U1 … due to 16A changeover contact. Also available as compact flush-mounted version RSW U1 with 13A NO contact … RSW 1 / RSS U1 (61.8 KiB) Power rating of relay contacts (301.9 KiB) Technical data RSW 1 (230V AC) Type … Download db_rsw1_rssu1_en.pdf, Download pr_relay_contacts_en.pdf … AC), Download db_rsw1_rssu1_en.pdf, Download
https://www.schalk.de/relays-pulse-switches/articles/rsw-1.en.html - 67.95 KiB
RSW U1 [52.38% relevance]
1 CO 13A (FMD) , variants: 12V UC, 24V UC, 230V AC RSW U1 Switching relay with potential-free … in the voltage variants 12V UC, 24V UC, and 230V AC. Also available as RSW 1 rail-mounted variant. … : 43 x 43 x 18.5 mm Technical data RSW U1 (230V AC) Type: RSW U1 (230V AC) Item no.: RSWU19 EAN: … 4046929601221 Specifications: 230V AC, 1 CO potential-free Dimensions: 43 x 43 x 18.5 … mm RSW U1 (12V UC), , RSW U1 (230V AC), Download db_rsw1_rswu1_en.pdf, Download … Switching relay with potential-free changeover contact (UP) RSW U1 The monostable switching relay RSW … . The relay has a potential-free changeover contact (8mm creepage and clearance). Available in the … general control applications. With a switching capacity of 13A, the relay can also cope with high … sheet RSW U1 (334.5 KiB) Power rating of relay contacts (301.9 KiB) Technical data RSW U1 (12V UC) Type … Download db_rsw1_rswu1_en.pdf, Download pr_relay_contacts_en.pdf … AC), Download db_rsw1_rswu1_en.pdf, Download
https://www.schalk.de/relays-pulse-switches/articles/rsw-u1.en.html - 68.23 KiB
Measuring relays [47.62% relevance]
EBN U2 GSF 2 Limit-value switch for liquid, 230V AC 10A Read more … GSF 2 GSL 2 NEW: Limit switch … for light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) Read … GSP 2 Limit-value switch for liquid levels, 230V AC, 10A Read more … GSP 2 GSR 2 Limit-value switch … for rain, 230V AC 10A Read more … GSR 2 GSW 4 NEW: Limit switch … for wind 230V AC, 1 change-over contact 10A (potential free) Read … more … GSW 4 IMR 3 Current measuring relay, 230V AC 0.02-16A Read more … IMR 3 IMR F1 Current … measuring relay, window function, 230V AC 0.02 -16A Read more … IMR F1 IW 32 Current … monitoring relay, RFM, fault mem., 3x230V/400V AC, 1 CO Read more … NKR 5 NKR F1 Mains monitoring … light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) Read more … GSL 2 GSP 2 … : Limit switch for wind 230V AC, 1 change-over contact 10A (potential free) Read more … GSW 4 IMR 3
https://www.schalk.de/measuring-relays.html - 66.12 KiB
GSW 4 [47.62% relevance]
GSW 4 NEW: Limit switch for wind 230V AC, 1 change-over contact 10A (potential free) GSW … 4 Limit switch for wind 230V AC, 1 changeover 10A GSW 4 The GSW 4 is a … GSW409 EAN: 4046929301374 Specifications: 230V AC, measuring range wind force: 2-8 Bft. (approx. … : Limit switch for wind 230V AC, 1 change-over contact 10A (potential free) GSW 4 Limit switch for wind … is required. The potential-free change-over contact of the GSW 4 enables universal signalling to … : 2-8 Bft. (approx. 10-70km/h) 1 change-over contact 10A potential-free Dimensions: 18 x 55 mm GSW 4 … installation. We recommend the SMS U2 as a compact flush-mounted variant for wind evaluation. … flush-mounted variant for wind evaluation. Accessories: SW 4 Wind sensor with joint holder Further … 4 / SW 4 (EN) (436.9 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: GSW 4 Item no … Download db_gsw4_sw4_en.pdf, Download pr_relay_contacts_en.pdf … GSW 4, , Download db_gsw4_sw4_en.pdf, Download
https://www.schalk.de/measuring-relays/articles/gsw-4.en.html - 64.9 KiB
ZAS K2 [47.62% relevance]
is a complete set of devices, consisting of the active isolating relay ATR U2 and the magnetic contact … with §4 of the Firing Ordinance (Germany). The active isolating relay ATR U2 enables mains voltage … active isolating relay ATR U2 and the magnetic contact MKW 1. The set is ideally suited for supply air … . In conjunction with the MKW 1 magnetic contact, it is thus possible, for example, to implement … fans) with little effort. Due to the change-over contact the ATR U2 is extremely versatile. Applications … suited for supply air monitoring when operating extractor hoods in accordance with §4 of the Firing … air monitoring when operating extractor hoods in accordance with §4 of the Firing Ordinance (Germany). The … be switched very easily using extra-low voltage contacts. There is no need for a power supply unit, as … 1 (set ZAS K2) (604.9 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: ZAS K2 Item no … db_atru2_mkw1_zask2_en.pdf, Download
https://www.schalk.de/motor-controllers/articles/zas-k2.en.html - 61.73 KiB
ATR U2 [47.62% relevance]
ATR U2 Active isolating relay with 1 CO, 230V AC/24V DC PELV … ATR U2 Active isolating relay ATR U2 The active isolating relay enables mains voltage consumers … ATR U2 Active isolating relay with 1 CO, 230V AC/24V DC PELV ATR U2 Active isolating relay ATR U2 … ATRU29 EAN: 4046929601160 Specifications: 230V AC, 1 CO 10A Dimensions: 43 x 43 x 18.5 mm , … be switched very easily using extra-low voltage contacts. There is no need for a power supply unit, as … 1 (set ZAS K2) (604.9 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: ATR U2 Item no … db_atru2_mkw1_zask2_en.pdf, Download pr_relay_contacts_en.pdf … . In conjunction with the MKW 1 magnetic contact, it is thus possible, for example, to implement … fans) with little effort. Due to the change-over contact the ATR U2 is extremely versatile. Applications … , Download db_atru2_mkw1_zask2_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/relays-pulse-switches/articles/atr-u2.en.html - 61.04 KiB