Search
Enter your search text here.
Results 36 - 42 of 134 for ac
EBN U2
current limiter (flush-mounting) EBN U2 The compact flush-mounted version EBN U2 is used wherever … high power-on surge currents could damage relay contacts. Electronic ballast units, fluorescent lamps and … more than 100A! The same applies to compensation capacitors. If the EBN 2 / EBN U2 is connected downstream … of the endangered contacts, current peaks are reduced to an uncritical … EBNU29 EAN: 4046929301190 Specifications: 230V AC, 1 NO 10A, tv=15ms Dimensions: 43 x 43 x 18.5 mm
https://www.schalk.de/measuring-relays/articles/ebn-u2.en.html
IMR F1
relay IMR F1 is used for current monitoring of AC loads. The "I Low" and "I High" switching … time has elapsed. The potential-free change-over contact can be used to switch on warning devices, for … -on pulse in order to put the affected consumer back into operation after it has been switched off. … The IW 32 current transformer available as an accessory extends the maximum possible measuring range … 16 A to 60 A. Applications Current monitoring of AC loads such as e.g. machines, drives, switchgear … , etc. Accessories Current transformer IW 32 Additional information … Datasheet IMR F1 / IW 32 Power rating of relay contacts Technical data Type: IMR F1 Item no.: IMRF19 EAN … : 4046929301022 Specifications: I-range: 230V AC, 20mA-16A, 1 CO 16A Dimensions: 18 x 55 mm … Current measuring relay, window function, 230V AC 0.02 -16A
https://www.schalk.de/measuring-relays/articles/imr-f1.en.html
Relays, pulse switches
Relays, pulse switches ATR 2D NEW: Active double isolating relay 230V AC / 24V DC PELV, 2 … changeover contacts Read more … ATR 2D ATR U2 Active isolating relay with 1 CO, 230V AC/24V DC PELV … more … ATR U2 ESR 1 Energy-Storage-Relay 230V AC Read more … ESR 1 ISK 41 Central pulse switch … ISK 42 Central pulse switch with ZI and 2 relay contacts Read more … ISK 42 ISS 1 Pulse switch 230V AC, 1 … 16A Read more … ISS 1 ISS U1 Pulse switch 230V AC, 1 NO 10A (UP) Read more … ISS U1 RDW 1 Double … relay, 2 change-over contacts 10A, versions: 2x24V UC, 2x230V AC Read more … … 1 Quadruple relay, 4 NO 10A, versions: 4x230V AC, 4x24V UC Read more … RQS 1 RSW 1 Switching and … relay, 1 CO 16A, versions: 12V UC, 24V UC, 230V AC Read more … RSW 1 RSW U1 Switching and control … 1 CO 13A (FMD) , variants: 12V UC, 24V UC, 230V AC Read more … RSW U1 RSW 2 Universal switching and
https://www.schalk.de/relays-pulse-switches.html
DJS 6 (230V AC)
Motor controllers DC blind controller 230V AC, for motors 12-24V DC (ext. supply) DJS 6 (230V … AC) DJS 6 (230V AC) The DJS 6 (230V AC, rail-mounted device) is a universally … . for venetian blinds, external venetian blinds, privacy blinds, etc. This variant is particularly … suitable for system conversions from AC motors to DC motors, as existing 230V control … the motor in case of mechanical blockage). Exact adjustment possibility of the lamellas in case … to be operated in a motor-friendly manner for privacy protection tasks. Adjustable fan-out function to … correct misalignment of individual slats. 230V AC (operating and control voltage), motor output 12 … operation modes: slats comfortably adjustable, privacy function, fan-out function automatic closing … sheet DJS 6 / DJS U6 (EN) Power rating of relay contacts Technical data Type: DJS 6 (230V AC) Item no.: … : Control inputs + operating voltage: 230V AC Outputs: 12-24V DC (external supply), 2 NO … : 18 x 55 mm NEW: DC blind
https://www.schalk.de/motor-controllers/articles/djs-6-230v-ac.en.html
SR 1
Measuring relays Rain sensor (capacitive) SR 1 Capacitive rain sensor with combined wall/mast mounting.
https://www.schalk.de/measuring-relays/articles/sr-1.en.html
RDW U1
relay with two potential-free change-over contacts (monostable). The monostable double relay RDW U1 … control input and the potential-free changeover contacts is 3 mm, the creepage and clearance distance … between the two changeover contacts is also 3 mm. The monostable relay is controlled … On the output side, 2 potential-free change-over contacts (11, 12, 14 or 21, 22, 24) are available. … U1 Datenblatt RDW U1 (DE) Power rating of relay contacts Technical data Type: RDW U1 Item no.: RDWU14 EAN
https://www.schalk.de/relays-pulse-switches/articles/rdw-u1.en.html
GSL 2
Limit switch for light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) GSL 2 … large number of systems is guaranteed. Suitable accessories SL 2 - Light sensor with clip holder Further … sheet GSL 2 / SL 2 (EN) Power rating of relay contacts Technical data Type: GSL 2 Item no.: GSL209 EAN … : 4046929301381 Specifications: 230V AC Shading: 20000-100000 Lux Twilight: 1-70 Lux … : Limit switch for light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free)
https://www.schalk.de/measuring-relays/articles/gsl-2.en.html