GSR 2 [23.81% relevance]
GSR 2 Limit-value switch for rain, 230V AC 10A GSR 2 Limit-value switch for rain GSR 2 The … GSR209 EAN: 4046929301237 Specifications: 230V AC, 1 CO potential-free 16A Dimensions: 18 x 55 mm … is needed. Matching product: Rain sensor SR 1 Accessories SR 1 Rain sensor Additional information … / SF 1 / SR 1 (516.0 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: GSR 2 Item no … db_gsf2_gsr2_sf1_sr1_en.pdf, Download pr_relay_contacts_en.pdf … , Download db_gsf2_gsr2_sf1_sr1_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/measuring-relays/articles/gsr-2.en.html - 63.04 KiB
MGR U2 [23.81% relevance]
MGR U2 Motor group relay, 230V AC 4 NO 5A, flush mounting version Control up to 2 … MGRU29 EAN: 4046929401050 Specifications: 230V AC, 4 NO 5A Dimensions: 43 x 43 x 18.5 mm MGR U2 … without having to use a separate control for each drive. The MGR U2 has two complete OPEN/CLOSE … MGR U1 / MGR U2 (72.7 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: MGR U2 Item no … db_mgru1_mgru2_en.pdf, Download pr_relay_contacts_en.pdf … U2, , Download db_mgru1_mgru2_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/motor-controllers/articles/mgr-u2.en.html - 60.89 KiB
MUR U1 [23.81% relevance]
building automation. As a rule, these extremely compact drive systems use DC motors and therefore cannot … with the conventional controllers designed for AC motors. The MUR U1 implements the AC control for … MUR U1 (404.1 KiB) Power rating of relay contacts (301.9 KiB) Technical data MUR U1 (12V DC) Type … , , Download db_muru1_en.pdf, Download pr_relay_contacts_en.pdf … mm MUR U1, , Download db_muru1_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/motor-controllers/articles/mur-u1.en.html - 64.54 KiB
NFA U2 [23.81% relevance]
NFA U2 Automatic mains field disconnector, 230V AC (UP) NFA U2 Automatic mains-field disconnector ( … Item no.: 4046929501019 Specifications: 230V AC, 1 NO 10A Dimensions: 43 x 43 x 18.5 mm NFA U2 … max. 10A) of the corresponding circuit. The very compact flush-mounted version NFA U2 can be installed in … / NFA U2 (IT) (971.8 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: NFA U2 Item no … db_nfa63_nfau2_it.pdf, Download pr_relay_contacts_en.pdf … .pdf, Download db_nfa63_nfau2_it.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/mains-field-disconnectors/articles/nfa-u2.en.html - 61.69 KiB
Why does the ZS no longer switch off the lights? [23.81% relevance]
of this problem is a sticking or welded relay contact. If problems of this kind arise in your system, … peaks in excess of 100 A! An unprotected relay contact cannot withstand such current peaks in the long … can be taken as a sure sign of a sticking relay contact. Last update on 2008-12-12 by webmaster … high switch-on peaks. Due to their input capacitance (up to 10 µF!), energy-saving lamps, ECG devices … EBN 2 or EBN U2) or by connecting the load via a contactor. If the LED indicating the switching state goes
https://www.schalk.de/faqreader_en/why-does-the-zs-no-longer-switch-off-the-lights.html - 52.29 KiB
Which points must be noted when using energy-saving lamps, fluorescent lamps, Tronic transformers and other ECG devices? [23.81% relevance]
and other ECG devices? Due to their input capacitance (up to 10 µF!), energy-saving lamps, ECG devices … -on peaks of up to 100 A! An unprotected relay contact cannot withstand such current peaks in the long … EBN 2 or EBN U2) or by connecting the load via a contactor. Further information on the loadability of … information on the loadability of relays with capacitive loads can be found in our corresponding data … sheet on the load carrying capability of relay contacts. Last update on 2008-12-12 by webmaster
https://www.schalk.de/faqreader_en/which-points-must-be-noted-when-using-energy-saving-lamps-fluorescent-lamps-tronic-transformers-and-other-ecg-devices.html - 52.75 KiB
Why does the ISK no longer switch off the lights? [23.81% relevance]
of this problem is a sticking or welded relay contact. If problems of this kind arise in your system, … -on peaks of up to 100 A! An unprotected relay contact cannot withstand such current peaks in the long … can be taken as a sure sign of a sticking relay contact. Last update on 2008-12-12 by webmaster … high switch-on peaks. Due to their input capacitance (up to 10 µF!), energy-saving lamps, ECG devices … EBN 2 or EBN U2) or by connecting the load via a contactor. If the LED indicating the switching state goes
https://www.schalk.de/faqreader_en/why-does-the-isk-no-longer-switch-off-the-lights.html - 52.29 KiB