MFS 2 [38.10% relevance]
control FS3 HS 2 and receiver FE3 SE (230V AC) MFS 2 The MFS 1 set is ideally suited, for … Specifications: Receiver: 1-channel, 230V AC, 1 W 10A Transmitter: 2 buttons/channels, 3V DC … x 18.5 mm FS3 H2: 57 x 35 x 11 mm FE3 SE (230V AC), , FS3 HS 2, Download db_fe3se_en.pdf, Download … MFS 1 set is ideally suited, for example, as a replacement for defective garage door radio controls for … and easily using the potential-free changeover contact on the receiver. Additional hand transmitters ( … FS3 HS 4 (EN) (834.6 KiB) Power rating of relay contacts (301.9 KiB) Practical tips for Schalk Radio … pdf, Download db_fs3hs_en.pdf, Download pr_relay_contacts_en.pdf, Download pt_radiorc_en.pdf … KiB) Power rating of relay contacts (301.9 KiB) Practical tips for Schalk Radio Switching System (29.1 KiB … .pdf, Download db_fs3hs_en.pdf, Download pr_relay_contacts_en.pdf, Download pt_radiorc_en.pdf
https://www.schalk.de/radio-switching-system/articles/mfs-2.en.html - 62.79 KiB
FV2 S [38.10% relevance]
Radio-connection transmitter with 4 inputs 230V AC (UP) FV2 S Radio connector transmitter FV2 S … E / FV2 S (746.7 KiB) Technical data FV2 S (230V AC) Type: FV2 S (230V AC) Item no.: FV2S09 EAN: … 4046929101264 Specifications: 230V AC, 4 inputs Dimensions: 43 x 43 x 18.5mm FV2 S ( … 230V AC), , Download db_fv2e_fv2s_en.pdf … FV2 S has 4 inputs for connecting external contacts/sensors. Any changes in the signals at the … directly by wireless transmission to the relay contacts of one or more radio-controlled switches of the … lamps with an existing lamp, transmitting the contact of a motion sensor to several lamps,
https://www.schalk.de/radio-connection-system/articles/fv2-s.en.html - 61.15 KiB
GSL 2 [38.10% relevance]
: Limit switch for light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) GSL 2 … Limit switch for light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) GSL 2 … GSL209 EAN: 4046929301381 Specifications: 230V AC Shading: 20000-100000 Lux Twilight: 1-70 Lux … light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) GSL 2 Limit switch for … light (shading/twilight) 230V AC, 1 changeover contact 10A (potential-free) GSL 2 The GSL 2 is a … large number of systems is guaranteed. Suitable accessories SL 2 - Light sensor with clip holder Further … 2 / SL 2 (EN) (380.0 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: GSL 2 Item no … , Download db_gsl2_sl2_en.pdf, Download pr_relay_contacts_en.pdf … , SL 2, Download db_gsl2_sl2_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/measuring-relays/articles/gsl-2.en.html - 63.37 KiB
ESR 1 [38.10% relevance]
ESR 1 Energy-Storage-Relay 230V AC ESR 1 Energy storage relay ESR 1 Mechanical … : ESR109 EAN: 4046929601177 Specifications: 230V AC Dimensions: 18 x 55 mm ESR 1, , Download … AC ESR 1 Energy storage relay ESR 1 Mechanical contactors can be kept in switched state at no power by … is not generally applicable. For example, if a contactor has to fall back automatically to off-state when … on pulse and stores energy. Thus, it can bring a contactor not only in the mechanical latch, but also … . For example, if a contactor has to fall back automatically to off-state when the mains fails … ESR 1 (330.2 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: ESR 1 Item no: … 1, , Download db_esr1_de.pdf, Download pr_relay_contacts_en.pdf … 55 mm ESR 1, , Download db_esr1_de.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/relays-pulse-switches/articles/esr-1.en.html - 61.54 KiB
ISK 42 [38.10% relevance]
ISK 42 Central pulse switch with ZI and 2 relay contacts ISK 42 Central pulse switch ISK 42 with … 41 / ISK 42 (523.2 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: ISK 42 Item no … db_isk41_isk42_en.pdf, Download pr_relay_contacts_en.pdf … pulse switch ISK 42 with additional relay contact and ZI ISK 42 In electrical installations with … . The ISK 42 has a second potential-free relay contact (10A, normally open) and a central pulse input. … on the power side and can be controlled with AC or DC voltages of 8-230 V. Central inputs (galv … ISK429 EAN: 4046929601047 Specifications: 230V AC, 2 NO 16A/10A, potential-free, Control inputs ZE … relay output. Applications Central lighting activation by means of burglar alarm systems with presence … 42, , Download db_isk41_isk42_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/relays-pulse-switches/articles/isk-42.en.html - 61.84 KiB
RQS 1 [38.10% relevance]
1 Quadruple relay, 4 NO 10A, versions: 4x230V AC, 4x24V UC RQS 1 Quadruple relay RQS 1 Switching … : 18 x 55 mm Technical data RQS 1 (230V AC) Type: RQS 1 (230V AC) Item no.: RQS109 EAN: … 4046929601085 Specifications: 230V AC, 4 NO 10A Dimensions: 18 x 55 mm RQS 1 (4 x 24V … UC), , RQS 1 (4 x 230V AC), Download db_rqs1_en.pdf, Download … relay for roller shutter controls or as space-saving coupling relay (1 module width = 18 mm). … RQS 1 (384.1 KiB) Power rating of relay contacts (301.9 KiB) Technical data RQS 1 (24V UC) Type: … AC), Download db_rqs1_en.pdf, Download pr_relay_contacts_en.pdf … 4 x 230V AC), Download db_rqs1_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/relays-pulse-switches/articles/rqs-1.en.html - 64.22 KiB
Products [33.33% relevance]
stairs or large halls, enhancement of switching capacities, etc. Go to related products... Measuring relays … , DIN rail clips, magnetic contacts, mains capacities, mains monitoring devices, etc. Go to related … -close motors, exhaust hoods when having open fireplaces, etc. Go to related products... Mains-field … devices, etc. Go to related products... Accessories Accessories to extend existing controls with … with batteries, DIN rail clips, magnetic contacts, mains capacities, mains monitoring devices, etc … high quality products are used properly, please contact your electrician