Search
Enter your search text here.
Results 50 - 56 of 132 for ac (0.0009 seconds)
NC 41 [33.33% relevance]
mounting version with four independent mains capacitors X2. Additional information Data sheet NC 1 / NC … or when the cable capacitance is too high. A capacitor from the button input to N or L compensates for … NC 41 Mains capacitance 4 x 330nF X2 230V AC NC 41 Mains capacitance NC 41 The NC 41 is used … NC4109 EAN: 4046929901024 Specifications: 230V AC Dimensions: 17.5 x 55 mm NC 41, , Download … NC 41 Mains capacitance 4 x 330nF X2 230V AC NC 41 Mains capacitance NC … push-button cable is too high or when the cable capacitance is too high. A capacitor from the button input
https://www.SCHALK.DE/accessories/articles/nc-41.en.html - 21.7 KiB
GSP 2 [28.57% relevance]
GSP 2 Limit-value switch for liquid levels, 230V AC, 10A GSP 2 Limit-value switch for liquid level … GSP209 EAN: 4046929301299 Specifications: 230V AC, 1 CO 10A (potential free) Dimensions: 18 x 55 … can be monitored. The potential free changeover contact (10A) is used to control for example an … process. Suitable electrode holders: SP 1 , SP 3 Accessories Level sensor SP 1 Level sensor SP 3 Additional … / SP 1 / SP 3 (429.7 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: GSP 2 Item no … db_gsp2_sp1_sp3_de.pdf, Download pr_relay_contacts_en.pdf … SP 3, Download db_gsp2_sp1_sp3_de.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/measuring-relays/articles/gsp-2.en.html - 75.95 KiB
NKR 5 [28.57% relevance]
monitoring relay, RFM, fault mem., 3x230V/400V AC, 1 CO NKR 5 Mains monitoring relay, RFM, fault … mem., 3x230V/400V AC, 1 CO NKR 5 The NKR 5 mains monitoring relay is … NKR509 EAN: 4046929301046 Specifications: 230V AC, 1 W 16A Uvar: 150-230V Ufix: 196V Dimensions: … automatically after power returns or only after acknowledgement (restart interlock). The error case can be … NKR 5 (EN) (347.7 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: NKR 5 Item no … 5, , Download db_nkr5_en.pdf, Download pr_relay_contacts_en.pdf … 55 mm NKR 5, , Download db_nkr5_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/measuring-relays/articles/nkr-5.en.html - 61.42 KiB
NFA 63 [28.57% relevance]
NFA 63 Automatic mains field disconnector, 230V AC NFA 63 Automatic mains field disconnector, 230V … NFA639 EAN: 4046929501033 Specifications: 230V AC, 1 S 16A tve/tva 0.1s/8s Uü 2.5V DC Dimensions: … The NFA 63 can also be switched on by external activation via its additional control input (B1). In this … / NFA U2 (IT) (971.8 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: NFA 63 Item no … db_nfa63_nfau2_it.pdf, Download pr_relay_contacts_en.pdf … .pdf, Download db_nfa63_nfau2_it.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/mains-field-disconnectors/articles/nfa-63.en.html - 61.52 KiB
ISK 41 [28.57% relevance]
supply side by optocouplers. A potential-free NO contact is available on the output side. In contrast to … on the power side and can be controlled with AC or DC voltages of 8-230 V. Central inputs (galv … ISK419 EAN: 4046929601030 Specifications: 230V AC, 1 NO 16A, potential-free Central inputs: ZE, ZA … ZA (central OFF) Applications Central lighting activation by means of burglar alarm systems with presence … 41 / ISK 42 (523.2 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: ISK 41 Item no … db_isk41_isk42_en.pdf, Download pr_relay_contacts_en.pdf … ISK 42, Download db_isk41_isk42_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/relays-pulse-switches/articles/isk-41.en.html - 61.83 KiB
RDW U1 [28.57% relevance]
relay with two potential-free change-over contacts (monostable). The monostable double relay RDW U1 … control input and the potential-free changeover contacts is 3 mm, the creepage and clearance distance … between the two changeover contacts is also 3 mm. The monostable relay is controlled … On the output side, 2 potential-free change-over contacts (11, 12, 14 or 21, 22, 24) are available. … RDW U1 (DE) (244.4 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: RDW U1 Item no … pdf, Download db_rdwu1_de.pdf, Download pr_relay_contacts_en.pdf … .pdf, Download db_rdwu1_de.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/relays-pulse-switches/articles/rdw-u1.en.html - 61.17 KiB
NR 3 [28.57% relevance]
NR 3 Time-delay relay, 230V AC NR 3 Time-delay relay with adjustable switch-on … NR3009 EAN: 4046929801096 Specifications: 230V AC, 1 CO pf 10A On-delay 0.3s - 4min Off-delay 6s - … times, the NR 3 is extremely versatile in practical applications. Also available as flush-mount … of a wide variety of loads, hotel room card contact etc. Additional information Datasheet NR 3 / NR … NR 3 / NR U3 (432.8 KiB) Power rating of relay contacts (301.9 KiB) Technical data Type: NR 3 Item no.: … , Download db_nr3_nru3_en.pdf, Download pr_relay_contacts_en.pdf … , , NR U3, Download db_nr3_nru3_en.pdf, Download pr_relay_contacts_en.pdf
https://www.schalk.de/timer-relays-clock-generators/articles/nr-3.en.html - 61.07 KiB